Manual of Inducible Nitric Oxide Synthase (iNOS) ELISA Kit
This reagent is for research purpose only: This kit is used to determine the content of inducible NO synthase (iNOS) in human serum, plasma and related liquid samples.
Experimental principle:
This kit uses the double antibody sandwich method to determine the level of human inducible NO synthase (iNOS) in the specimen. The microplate was coated with purified anti-human iNOS antibody to make a solid phase antibody. Inducible NO synthase (iNOS) was added to the monoclonal antibody-coated microwells in turn, and then combined with HRP-labeled iNOS antibody to form an antibody -Antigen-enzyme labeled antibody complex, after thorough washing, add substrate TMB to develop color. TMB is converted into blue under the catalysis of HRP enzyme, and into the final yellow under the action of acid. The color depth is positively correlated with the inducible NO synthase (iNOS) in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of human inducible NO synthase (iNOS) in the sample was calculated by a standard curve.
Kit composition:
Kit composition
48 hole configuration
96-well configuration
save
Instructions
1 serving
1 serving
Sealing film
2 pieces (48)
2 pieces (96)
sealed bag
1
1
Enzyme coated plate
1 × 48
1 × 96
Store at 2-8 ℃
Standard product: 45U / L
0.5ml × 1 bottle
0.5ml × 1 bottle
Store at 2-8 ℃
Standard dilution
1.5ml × 1 bottle
1.5ml × 1 bottle
Store at 2-8 ℃
Enzyme reagent
3 ml × 1 bottle
6 ml × 1 bottle
Store at 2-8 ℃
Sample diluent
3 ml × 1 bottle
6 ml × 1 bottle
Store at 2-8 ℃
Developer A liquid
3 ml × 1 bottle
6 ml × 1 bottle
Store at 2-8 ℃
Developer B liquid
3 ml × 1 bottle
6 ml × 1 bottle
Store at 2-8 ℃
Stop solution
3ml × 1 bottle
6ml × 1 bottle
Store at 2-8 ℃
20 times concentrated washing liquid
20ml × 1 bottle
30ml × 1 bottle
Store at 2-8 ℃
Sample processing and requirements:
1. Serum: room temperature blood coagulates naturally for 10-20 minutes, centrifuged for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully and centrifuge again if a precipitate appears during storage.
2. Plasma: EDTA or sodium citrate should be selected as the anticoagulant according to the requirements of the specimen, mixed for 10-20 minutes, and centrifuged for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, it should be centrifuged again.
3. Urine: collected in a sterile tube and centrifuged for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, centrifuge again. Pleural and ascites, cerebrospinal fluid reference implementation.
4. Cell culture supernatant: When detecting secreted components, collect with a sterile tube. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. When detecting the components inside the cells, dilute the cell suspension with PBS (PH7.2-7.4), and the cell concentration will reach about 1 million / ml. Through repeated freezing and thawing, the cells are destroyed and the intracellular components are released. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, it should be centrifuged again.
5. Organize the specimen: after cutting the specimen, weigh it. Add a certain amount of PBS, PH7.4. Quickly freeze and save with liquid nitrogen for later use. After the specimen melts, it still maintains a temperature of 2-8 ° C. Add a certain amount of PBS (PH7.4) and homogenize the specimen with a manual or homogenizer. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. After aliquoting, a portion is to be tested, and the rest is frozen for future use.
6. The specimen should be extracted as soon as possible after collection. The extraction should be carried out according to relevant literature. The experiment should be carried out as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided.
7. The sample containing NaN3 cannot be detected because NaN3 inhibits the activity of horseradish peroxidase (HRP).
Steps
1. Dilution and loading of standard products: set 10 standard wells on the enzyme-coated plate, add 100 μl of standard products in the first and second wells, and then add standard products in the first and second wells 50μl of diluent, mix well; then take 100μl from the first well and the second well and add them to the third and fourth wells respectively, and then add 50μl of standard diluent to the third and fourth wells respectively, mix well; Then take 50μl each in the third and fourth wells and discard it, then add 50μl each to the fifth and sixth wells, and then add 50ul of the standard dilution solution to the fifth and sixth wells respectively, and mix well; After mixing, take 50μl from the fifth and sixth wells and add them to the seventh and eighth wells respectively. Then add 50μl of the standard dilution solution to the seventh and eighth wells respectively. Take 50μl from the eight wells and add them to the ninth and tenth wells. Then add 50μl of the standard dilution solution to the ninth and tenth wells. After mixing, take 50μl from the ninth and tenth wells and discard. (After dilution, the volume of each well is 50μl, and the concentration is 30U / L, 20U / L, 10U / L, 5U / L, 2.5U / L).
2. Add samples: set up blank wells (the blank control wells do not add samples and enzyme reagents, the rest of the steps are the same) and the sample wells to be tested. Add 40μl of sample diluent to the test sample well of the enzyme-coated plate, and then add 10μl of the sample to be tested (the final dilution of the sample is 5 times). Add the sample and add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, shake gently to mix.
3. Incubation: Seal the plate with a sealing plate and incubate at 37 ° C for 30 minutes.
4. Mixing solution: dilute 20 times concentrated washing liquid with distilled water 20 times and reserve.
5. Washing: Carefully peel off the sealing film, discard the liquid, spin dry, fill each well with the washing liquid, let it stand for 30 seconds and then discard, repeat this 5 times, pat dry.
6. Add enzyme: add 50μl of enzyme label reagent to each well, except blank well.
7. Incubation: The operation is the same as 3.
8. Washing: The operation is the same as 5.
9. Color development: add 50μl of developer A to each well, then add 50μl of developer B, mix gently, and develop at 37 ° C in the dark for 15 minutes.
10. Termination: Add 50μl of stop solution to each well to stop the reaction (at this time the blue will turn to yellow).
11. Determination: Measure the absorbance (OD value) of each well in sequence with the blank air conditioner at zero and 450 nm wavelength. The measurement should be carried out within 15 minutes after adding the stop solution.
Precautions:
1. The kit should be equilibrated at room temperature for 15-30 minutes before being taken out of the refrigerated environment. If the enzyme label coated plate is unopened, the strip should be stored in a sealed bag.
2. Crystals may be precipitated in the concentrated washing liquid, which can be heated and dissolved in a water bath during dilution, and the results will not be affected during washing.
3. The sampler should be used at each step of sample addition, and the accuracy should be regularly checked to avoid test errors. It is best to control the sampling time within 5 minutes. If there are many specimens, it is recommended to use a volley gun to add samples.
4. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the test substance in the specimen is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please first dilute it with a certain multiple (n times) of the sample diluent and then determine it. When calculating, please multiply the total dilution Multiple (× n × 5).
5. The sealing film is limited to one-time use to avoid cross-contamination.
6. Please keep the substrate away from light.
7. Strictly follow the instructions, and the test results must be determined by the microplate reader.
8. All samples, washing liquids and various wastes should be treated as infectious agents.
9. The components of different batches of this reagent shall not be mixed.
10. If there is any difference with the English manual, the English manual shall prevail.
Calculation:
Taking the concentration of the standard as the abscissa and the OD value as the ordinate, draw a standard curve on the coordinate paper, and find the corresponding concentration from the standard curve according to the OD value of the sample; then multiply by the dilution factor; Calculate the linear regression equation of the standard curve with the OD value, substitute the OD value of the sample into the equation, calculate the sample concentration, and multiply it by the dilution factor to obtain the actual concentration of the sample.
1. The correlation coefficient R between the linear regression of the sample and the expected concentration is more than 0.990.
2. The batch and approval shall be less than 9% and 11% respectively
examination range:
1.5U / L – 40U / L
Storage conditions and validity period:
1. Store the kit: 2-8 ℃.
2. Validity: 6 months
Lantern
Decorative Lantern for patio, home and room decor.
Not only for home use our Lantern are great for corporate events, restaurants, weddings, various holidays and parties. With a large selection of color choices you're sure to find a match to your theme.
Create the perfect ambiance - light up your back porch/deck or add the perfect touch of low light to your living room. The unique color and shape of the jars add a stylish detail to any room.
Versatile
Give your home decor some character with these charming lanterns. Not just for event decor, WILL TRADE Lantern can be used throughout your home from living room decor to Farmhouse kitchen décor to the back patio to a bathroom shelf, there are so many ways to create a warm atmosphere for your family as well as your guests.
Perfect Ambiance
There is nothing more romantic than candlelit evenings under the stars. Create that feeling every time you use our Lantern. Whether using them on your table, fire place mantle, shelf decor, fall decor, bathroom decor, hanging them from your tree branches or lining the aisles with them, WILL TRADE has designed a lantern just for your occasion.
Decorative Candle Lantern, Candle Holder, Tealight Lanterns, Hanging Candle Holder, etc.
HISMOK(SHENZHEN)TECHNOLOGY CO.,LTD , https://www.willtrademat.com