Free ELISA test kit for human dengue virus antibody

Human dengue virus antibody ELISA detection kit This reagent is for research use only Specimen: Serum or plasma Test principle: DV-Ab kit is an indirect enzyme-linked immunosorbent assay (ELISA). Known DV-Ab concentration standard, unknown The concentration of the sample is added to the microplate for detection. First, the DV-Ab and biotin-labeled antibody were incubated simultaneously. After washing, HRP labeled with avidin was added. After incubation and washing, the unbound enzyme conjugate is removed, and then substrates A and B are added to act simultaneously with the enzyme conjugate. Produce colors. The color depth is proportional to the concentration of DV-Ab in the sample. Bring your own material distilled water. Sampler: 5ul, 10ul, 50ul, 100ul, 200ul, 500ul, 1000ul. Oscillator and magnetic stirrer etc. Safety Avoid direct contact with the stop solution and substrates A and B. Once exposed to these liquids, rinse with water as soon as possible. Do not eat, drink, smoke or use cosmetics during the experiment. Do not use your mouth to absorb any ingredients in the kit. Handling precautions Reagents should be stored according to label instructions, and returned to room temperature before use. The sparse standards should be discarded and cannot be stored. The slats not used in the experiment should be immediately returned to the packaging bag, sealed and stored to avoid deterioration. Unused other reagents should be packed or covered. Do not mix reagents of different batches. Use before warranty. Use a disposable pipette tip to avoid cross-contamination, and avoid using a sampler with a metal part when drawing the stop solution and substrates A and B. Use a clean plastic container to prepare the washing solution. Mix all components and samples in the kit thoroughly before use. When washing the enzyme-labeled plate, it should be fully patted dry. Substrate A should evaporate to avoid opening the lid for a long time. Substrate B is sensitive to light and avoid prolonged exposure to light. Avoid contact with hands, it is toxic. The OD value should be read immediately after the experiment is completed. The order of adding reagents should be the same to ensure that all wells are incubated for the same time. Perform the incubation operation according to the time, the amount and order of the liquid indicated in the instructions. Human Dengue virus antibody ELISA detection kit sample collection, processing and storage methods Serum ----- Avoid any cell stimulation during the operation. Use test tubes free of pyrogens and endotoxins. After collecting blood, centrifuge at 1000 × g for 10 minutes to separate the serum and red blood cells quickly and carefully. Plasma ----- EDTA, citrate, heparin plasma can be used for detection. Centrifuge at 1000 × g for 30 minutes to remove particles. The cell supernatant was centrifuged at 1000 × g for 10 minutes to remove particles and polymers. Storage ------ If the sample is not used immediately, it should be divided into small parts and stored at -70 ℃ to avoid repeated freezing. If possible, do not use hemolysis or hyperlipidemia. If there are a large number of particles in the serum, centrifuge or filter before testing. Do not thaw at 37 ° C or higher. Thaw at room temperature and ensure that the sample is thawed evenly and adequately. Reagent preparation standards: Serial dilutions of standards should be prepared during the experiment and cannot be stored. Before dilution, the standard was mixed by shaking. Dilution of washing buffer (50 ×): 50-fold dilution with distilled water. Before use, mix all reagents thoroughly. Don't make the liquid generate a lot of foam, so as to avoid adding a large number of bubbles during sample addition, which will cause errors in sample addition. The number of slats required is determined by the number of samples to be tested plus the number of standard products. It is recommended to make multiple holes for each standard and blank hole. Each sample is determined according to its own quantity, and those that can use multiple holes can be used as much as possible. Add 50ul of the diluted standard to the reaction well and 50ul of the sample to be tested in the reaction well. Immediately add 50ul of biotin-labeled antibody. Cover the membrane plate, gently shake and mix, and incubate at 37 ° C for 1 hour. Shake off the liquid in the wells, fill each well with washing liquid, shake for 30 seconds, shake off the washing liquid, pat dry with absorbent paper. Repeat this operation 3 times. If washing with a plate washer, the number of washes is increased once. Add 80 ul of streptavidin-HRP to each well, gently shake and mix, and incubate at 37 ° C for 30 minutes. Shake off the liquid in the wells, fill each well with washing liquid, shake for 30 seconds, shake off the washing liquid, pat dry with absorbent paper. Repeat this operation 3 times. If washing with a plate washer, the number of washes is increased once. Add 50ul of substrate A and B to each well, mix gently by shaking, and incubate at 37 ° C for 10 minutes. Avoid light. Remove the enzyme labeling plate and quickly add 50ul of stop solution. After adding the stop solution, the results should be measured immediately. The OD value of each well was measured at a wavelength of 450 nm. The results of the human dengue virus antibody ELISA detection kit limited to standard No. 6 and above are non-linear, and accurate results cannot be obtained according to this standard curve. Kit performance 1. Sensitivity: The minimum detection concentration is less than No. 1 standard. Linearity of dilution. The correlation coefficient between the linear regression of the sample and the expected concentration is 0.990. 2. Specificity: Does not react with other cytokines. 3. Repeatability: The coefficients of variation within and between plates are less than 10%. Judgment and analysis of results 1. Instrument value: read the OD value of each well on a microplate reader with a wavelength of 450 nm. 2. Take the absorbance OD value as the ordinate (Y), and the corresponding DV-Ab standard concentration as the abscissa (X ), The corresponding curve is made, and the DV-Ab content of the sample can be converted from the standard curve to the corresponding concentration according to its OD value. 3. Detection value range: 0-40IU / L4, sensitivity: 0.1 IU / L human dengue virus antibody ELISA detection kit DA2002-0.2ml ZEBRA / HHV4 / EBV (Human herpesvirus 4 type 2 / epstein-barr virus) human herpes Virus 4 antibody 0.2ml DA1956-0.2ml GTP-CH-1 guanosine triphosphate cyclohydrolase antibody 0.2ml DA1957-0.2ml GTSE-1 (G2 and S phase-expressed protein 1) G2 phase, S phase response related protein 1 antibody 0.2 mlDA1958-0.2ml A / H5N1-M2 (Avian influenza Matrix Protein-2) Avian influenza virus H5N1-M2 protein antibody 0.2ml DA1961-0.1ml Influenza A Virus Hemagglutinin [A / California / 04/2009 (H1N1) Influenza A Viral hemagglutinin antibody 0.1ml DA1961-0.1ml Influenza A Virus Hemagglutinin [A / California / 04/2009 (H1N1) Influenza A virus hemagglutinin antibody 0.1ml DA1961-0.2ml Influenza A Virus Hemagglutinin [A / California / 04/2009 (H1N1) Influenza A virus hemagglutinin antibody 0.2ml DA1962-0.3ml A / H2N2 (Influenza A virus, hemagglutinin H2N2) rabbit anti-A 2 (H2N2) subtype influenza antibody (A type 0.3ml DA1963-0.4ml H2AX (H2A histone family member X) histone H2AX antibody 0.4mlDA P044-0.1ml Phospho-Bad (Ser155)? Phospho-related death promoting factor antibody 0.1ml DAP045-0.1ml phospho-Bcl-xL (Ser62)? Phospho-Bcl-xL (pSer62) antibody 0.1ml

Disposable Biodegradable Tableware

100% fully biodegradable disposable tableware, including food containers and industrial packaging such as knives, forks, spoons, bowls, pots, cups, fresh trays, sushi cake boxes, etc. 100% fully biodegradable disposable tableware is made of pure PLA. It does not contain PE, PP, PS, PVC or PET.

Please bury the disposable Tableware utensils that have been used in the soil, or buried in a micro-organism environment, the compost can be 100% fully degraded into carbon dioxide and water in 3 months, becoming organic fertilizer, without white pollution.

Biodegradable Dinnerware Wedd,Biodegradable Disposable Plate,Eco Disposable Plates,Recyclable Plates And Cutlery

Shaoxing Lvxing New Material Co.,Ltd , https://www.greenstarpackage.com

Posted on